Frost Protection
Trace Heating
Our systems are an energy-efficient solution of self-regulating heating cables and a smart control unit which will monitor the temperature and only activate when and where necessary.
Keeping your pipes working in cold conditions can prove difficult, thermal insulation alone cannot fully protect them from freezing and harsh weather which can cause significant problems that could be avoided.
With Frost Protection for pipes, vital systems including water pipes, fire mains, sprinkler systems and fuel oil lines are safeguarded from frost in severe winter conditions. The technology consists of smart heating cables which monitor the pipes temperature and adjust their output accordingly combined with central control units which analyse the heating requirements and calculate the optimum settings as a function of the ambient or pipe temperature.
By monitoring the temperature and only activating when and where necessary this energy-efficient solution of self-regulating heating cables and smart control units will not only protect the pipes but also reduce total operating and total installed costs.
Thermal Insulation
Why do we insulate?
Condensation control
Where pipes operate at below-ambient temperatures, the potential exists for water vapour to condense on the pipe surface. Moisture is known to contribute towards many different types of corrosion, so preventing the formation of condensation on pipework is usually considered important.
Pipe insulation can prevent condensation forming, as the surface temperature of the insulation will vary from the surface temperature of the pipe. Condensation will not occur, provided that (a) the insulation surface is above the dew point temperature of the air; and (b) the insulation incorporates some form of water-vapour barrier or retarder that prevents water vapour from passing through the insulation to form on the pipe surface.
Pipe freezing
Since some water pipes are located either outside or in unheated areas where the ambient temperature may occasionally drop below the freezing point of water, any water in the pipework may potentially freeze. When water freezes, it expands due to negative thermal expansion, and this expansion can cause failure of a pipe system in any one of a number of ways.
Pipe insulation cannot prevent the freezing of standing water in pipework, but it can increase the time required for freezing to occur, thereby reducing the risk of the water in the pipes freezing. For this reason, it is recommended to insulate pipework at risk of freezing, and local water-supply regulations may require pipe insulation be applied to pipework to reduce the risk of pipe freezing.
For a given length, a smaller-bore pipe holds a smaller volume of water than a larger-bore pipe, and therefore water in a smaller-bore pipe will freeze more easily (and more quickly) than water in a larger-bore pipe (presuming equivalent environments). Since smaller-bore pipes present a greater risk of freezing, insulation is typically used in combination with alternative methods of freeze prevention (e.g., modulating trace heating cable, or ensuring a consistent flow of water through the pipe).
Energy saving
Since pipework can operate at temperatures far removed from the ambient temperature, and the rate of heat flow from a pipe is related to the temperature differential between the pipe and the surrounding ambient air, heat flow from pipework can be considerable. In many situations, this heat flow is undesirable. The application of thermal pipe insulation introduces thermal resistance and reduces the heat flow.
Thicknesses of thermal pipe insulation used for saving energy vary, but as a general rule, pipes operating at more-extreme temperatures exhibit a greater heat flow and larger thicknesses are applied due to the greater potential savings.
The location of pipework also influences the selection of insulation thickness. For instance, in some circumstances, heating pipework within a well-insulated building might not require insulation, as the heat that's "lost" (i.e., the heat that flows from the pipe to the surrounding air) may be considered “useful” for heating the building, as such "lost" heat would be effectively trapped by the structural insulation anyway. Conversely, such pipework may be insulated to prevent overheating or unnecessary cooling in the rooms through which it passes.
Protection against extreme temperatures
Where pipework is operating at extremely high or low temperatures, the potential exists for injury to occur should any person come into physical contact with the pipe surface. The threshold for human pain varies, but several international standards set recommended touch temperature limits.
Since the surface temperature of insulation varies from the temperature of the pipe surface, typically such that the insulation surface has a "less extreme" temperature, pipe insulation can be used to bring surface touch temperatures into a safe range.
Control of noise
Pipework can operate as a conduit for noise to travel from one part of a building to another (a typical example of this can be seen with waste-water pipework routed within a building). Acoustic insulation can prevent this noise transfer by acting to dampen the pipe wall and performing an acoustic decoupling function wherever the pipe passes through a fixed wall or floor and wherever the pipe is mechanically fixed.
Pipework can also radiate mechanical noise. In such circumstances, the breakout of noise from the pipe wall can be achieved by acoustic insulation incorporating a high-density sound barrier.
We have a varied range of insulation products and will be more than happy to discuss your requirements and tailor an offer to suit your specific needs.